Good energy

First choice: insulate EnEV-compliant

by 50 to 200 Percent. With additional

noise insulation.

Thinking outside the box

Linked competence: updated in all main areas
of technical building equipment. With the new

technical courses. Practical, effective and for free.

 

Preinsulated pipe

Missel delivery service: within
24 hours. Preinsulated pipes
from the factory directly to the
construction site.

Seamless and universal

Perfect matching and brand-
independent insulation for
fittings according to the EnEV

Wow gegen Tau

Echte Perle: Innenliegende Regenwasser-

leitungen einfach und sicher (nach)dämmen:

Mit praktischem Schnellverschluss und

diffusionsdichtem Klebestreifen.

Powerful approach

Resting on the ground: thermal
insulation for low floor assemblies.
Soundproof.

 

Under control

No trespassing: R90-fire safety
for mixed installations. Secure
pipe screening made of cast iron
and plastic pipes.

For generations well

Firm cohesion: fibre reinforced

wrapping strips for refitting

pipework insulation.

 

Fire and flames

A practical sleeve system: expels

fire and smoke through pipes

through walls and ceilings to the
outsides. Reliable operation of
R30 to R120 and according to the
current demands of the MLAR.

Silent hero

Peacemaker: a continuous
structure of sound prevention
equipment for insulation tubes
and fittings.


Good energy

First choice: insulate EnEV-compliant

by 50 to 200 Percent. With additional

noise insulation.

Missel fire protection insulation sleeves according to *MLAR

(*currently only available in Germany)

Piping must be fed through the walls and ceilings of a building in a safe way regarding fire protection. For this purpose the Missel brand has developed many safe and easy-to-assemble fire protection insulation sleeves. These guarantee the required smoke and fire tightness and also effectively insulates against sound.

Simple and quick assembly with a Velcro fastener!


Special advantages:
Flexible and adaptable material
Customer-specific special designs (shape) available
Small thickness 4 mm
Also possible to install subsequently in a later building phase
Structure-borne sound isolation
Tear-resistant surface through meshing
Certified and approved
Small core drill hole sizes

MSA® 4-BSM®

Application for relief of MLAR
Feeding pipes and electrical cables through F60/F90 walls and F60/F90 ceilings

Cast iron waste water pipes up to da ≤ 160 mm
Stainless steel waste water pipes up to da ≤ 160 mm
Rain water and fire extinguishing pipes made from steel and cast iron up to   
     da ≤ 160 mm
                                                                                                                              

   Details

   
 

BSM®-S

Application after the relaxation of the MLAR Directive
Feeding pipes and electrical cables
through F60/F90 walls and F60/F90 ceilings

Drinking water, gas and heating pipes made from copper and steel up to

     da ≤  160 mm
Drinking water and heating pipes made from multi-layer composites and  
     plastic up to da ≤ 32 mm
Laboratory and medical gas pipes made from non-combustible building
     materials up to da ≤ 160 mm
Sprinkler and fire extinguisher pipes
Pipes for solar and waste water treatment plants
Individual electrical cables such as power cables, computer, antennae and
     telephone cables without a diameter limit
Electrical cables in empty tubes made from plastic up to da ≤ 32 mm

 

 



BSM®-S 13

Application after the relaxation of the MLAR Directive with integrated heat insulation according to EnEV 2014
Feeding pipes and electrical cables through F60/F90 walls and F60/F90 ceilings
Drinking water, gas and heating pipes made from copper and steel up to

     da ≤ 160 mm
Drinking water and heating pipes made from multi-layer composites and 
     plastic up to da ≤ 32 mm


 


BSM®-L

Application after the relaxation of the M-LüAR Directive for non-combustible air ducts, and according to the Missel data Sheet about fire protection

Structure-borne sound isolated, length 400 mm, thickness 4 mm
 




BSM®-F30

Application with F30 walls after the relaxation of the MLAR Directive
Feeding piping through F30 walls
Non-combustible pipes – also with a flammable pipe lining
Drinking water, heating, solar equipment, fire extinguisher systems without a
     diameter limit
Waste water, rain water, water treatment plants without a diameter limit
Technical gases as well as laboratory and medical gases, ventilation
     pneumatic tube etc., without a diameter limit
Individual electrical pipes (such as power cables, computer, antennae and  
     telephone cables) as well as cable bundles up to 100mm external diameter  
     and cable routes of optional breadth