Preinsulated pipe

Missel delivery service: within
24 hours. Preinsulated pipes
from the factory directly to the
construction site.


Fire and flames

A practical sleeve system: expels

fire and smoke through pipes

through walls and ceilings to the
outsides. Reliable operation of
R30 to R120 and according to the
current demands of the MLAR.

Thinking outside the box

Linked competence: updated in all main areas
of technical building equipment. With the new

technical courses. Practical, effective and for free.

 

Seamless and universal

Perfect matching and brand-
independent insulation for
fittings according to the EnEV

Powerful approach

Resting on the ground: thermal
insulation for low floor assemblies.
Soundproof.

 

Good energy

First choice: insulate EnEV-compliant

by 50 to 200 Percent. With additional

noise insulation.

Under control

No trespassing: R90-fire safety
for mixed installations. Secure
pipe screening made of cast iron
and plastic pipes.

For generations well

Firm cohesion: fibre reinforced

wrapping strips for refitting

pipework insulation.

 

Silent hero

Peacemaker: a continuous
structure of sound prevention
equipment for insulation tubes
and fittings.

Wow gegen Tau

Echte Perle: Innenliegende Regenwasser-

leitungen einfach und sicher (nach)dämmen:

Mit praktischem Schnellverschluss und

diffusionsdichtem Klebestreifen.

Preinsulated pipe

Missel delivery service: within
24 hours. Preinsulated pipes
from the factory directly to the
construction site.

Misselfix-Garant G

 

Insulation for drinking water and structural level pipes (cold) according to DIN 1988-2 and DIN 1988-200 (standard since 2012) to reduce thermal absorption, the growth of legionella, sound transmission and to reduce condensation water, with integrated sound insulation.
The Misselfix-Garant sealant is equipped with a mesh foil and a fibre padded layer, through which structure-borne sound contacts from e.g. the extrusion of uneven building parts or stones are reliably avoided. The tear resistance and tear growth resistance compared to pure foam material is increased by up to ten times.

 

Misselfix-Garant G


Special advantages:

Thermal conduction coefficient λ10°C = 0.040W/(m•K)
Tear-resistant surface through a mesh and fibre padded layer
Insulation layer thicknesses for existing DIN 1988-2 (4mm)
Insulation layer thicknesses for DIN 1988-200 (9mm, 13mm)
Increased protection against legionella and condensation (6 to 13mm)
Pre-prepared shaped parts to reduce assembly times
Very good energy balance in production

Closed-cell polythene foam, protected externally through the tear-resistant meshing.